Detection of occult endoleaks after endovascular treatment of abdominal aortic aneurysm using magnetic resonance imaging with a blood pool contrast agent: preliminary observations.
Fulltext:
88385.pdf
Embargo:
until further notice
Size:
508.4Kb
Format:
PDF
Description:
Publisher’s version
Publication year
2010Source
Investigative Radiology, 45, 9, (2010), pp. 548-53ISSN
Annotation
01 september 2010
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Pathology
Radiology
Journal title
Investigative Radiology
Volume
vol. 45
Issue
iss. 9
Page start
p. 548
Page end
p. 53
Subject
NCEBP 14: Cardiovascular diseases; Medical Imaging - Radboud University Medical CenterAbstract
OBJECTIVE: To determine whether blood pool contrast agent-enhanced magnetic resonance imaging (MRI) can visualize endoleaks that are occult on computed tomography (CT) in patients with nonshrinking aneurysms after endovascular aneurysm repair. MATERIALS AND METHODS: Written informed consent was obtained for this prospective institutional review board approved study. Twelve patients with nonshrinking aneurysms but no evidence of endoleak on CT angiography and delayed CT underwent MRI with a blood pool contrast agent (Gadofosveset trisodium, Bayer Schering Pharma, Berlin, Germany). Patients could participate once in the study. T1-weighted images were acquired before injection, 3 minutes and 30 minutes after injection. Two blinded readers independently scored the images into "endoleak," "possible endoleak," or "no endoleak" by comparing postcontrast MR images with precontrast images. Weighted kappas with linear weighting scheme were calculated for interobserver agreement. RESULTS: One MRI examination was nondiagnostic because of patient motion. In the successful 11 MRI exams, MRI 3 minutes after injection demonstrated endoleak in 2/11 MRI exams (18%) and possible endoleak in 2/11 MRI exams (18%). After 30 minutes, MRI demonstrated endoleak in 6/11 scans (55%) and possible endoleak in 1/11 scans (9%). Weighted kappa was 0.78 and 0.89 for early and late postcontrast images. CONCLUSION: Endoleaks that are occult on CT can be detected by MRI with blood pool contrast agents. Late phase MRI 30 minutes after injection revealed additional endoleaks not seen 3 minutes after injection.
This item appears in the following Collection(s)
- Academic publications [246326]
- Electronic publications [133960]
- Faculty of Medical Sciences [93294]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.