Diagnostic value of 123I-ioflupane and 123I-iodobenzamide SPECT scans in 248 patients with parkinsonian syndromes.
Fulltext:
70052.pdf
Embargo:
until further notice
Size:
266.7Kb
Format:
PDF
Description:
Publisher’s version
Publication year
2008Source
European Neurology, 59, 5, (2008), pp. 258-66ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Neurology
Journal title
European Neurology
Volume
vol. 59
Issue
iss. 5
Page start
p. 258
Page end
p. 66
Subject
DCN 1: Perception and Action; UMCN 3.2: Cognitive neurosciencesAbstract
BACKGROUND: SPECT is one of the most employed techniques in the diagnostic workup of idiopathic Parkinson's disease (IPD). Despite its widespread use, the exact diagnostic accuracy of this technique in parkinsonian syndromes remains controversial. METHODS: In this study, we investigated the diagnostic accuracy of an initial (123)I-ioflupane (FP-CIT) and/or (123)I-iodobenzamide (IBZM) SPECT to differentiate between IPD and other parkinsonian disorders. 248 patients underwent a SPECT scan because of an as yet unclassified parkinsonian syndrome in our clinic between 2001 and 2006. Gold standard was the clinical diagnosis derived from the latest available clinical record, or, when this was not possible, a new complete physical and neurological examination by a blinded movement disorder specialist neurologist. Mean follow-up between SPECT and the latest clinical information was 18 months (range 3 months to 5 years). RESULTS: 223 of the 248 patients were clinically definitely diagnosed after follow-up: IPD 127, atypical parkinsonian syndromes (APS) 27, essential tremor (ET) 22, vascular parkinsonism (VP) 16, drug-induced parkinsonism (DIP) 5, doubt between PD and APS 2, other diseases without dopaminergic involvement 24. The mean odds ratio (95% CI) for FP-CIT SPECT's ability to distinguish between IPD and ET was 82 (11-674); between IPD and VP 61 (8-490); between IPD and DIP 36 (2-697) and between IPD and APS was 1 (0-4). The odds ratio for the IBZM SPECT tracer to differentiate between IPD and APS was 7 (2-17). CONCLUSIONS: FP-CIT SPECT is accurate to differentiate patients with IPD from those with ET, and IPD from VP and DIP. The accuracy of both FP-CIT and IBZM SPECT scans to differentiate between IPD and APS is low.
This item appears in the following Collection(s)
- Academic publications [248380]
- Electronic publications [135674]
- Faculty of Medical Sciences [94201]
Upload full text
Use your RU or RadboudUMC credentials to log in with SURFconext to upload a file for processing by the repository team.