[Alpha-foetoprotein assessment in amniotic fluid for the detection of neural tube defects: limited added value beyond week 20 ultrasound; retrospective study]

Fulltext:
69367.pdf
Embargo:
until further notice
Size:
88.54Kb
Format:
PDF
Description:
Publisher’s version
Publication year
2008Source
Nederlands Tijdschrift voor Geneeskunde, 152, 34, (2008), pp. 1876-81ISSN
Publication type
Article / Letter to editor

Display more detailsDisplay less details
Organization
Human Genetics
Health Evidence
Gynaecology
Chemical Endocrinology
Former Organization
Epidemiology, Biostatistics & HTA
Journal title
Nederlands Tijdschrift voor Geneeskunde
Volume
vol. 152
Issue
iss. 34
Page start
p. 1876
Page end
p. 81
Subject
EBP 2: Effective Hospital Care; IGMD 3: Genomic disorders and inherited multi-system disorders; IGMD 6: Hormonal regulation; UMCN 5.1: Genetic defects of metabolism; UMCN 5.2: Endocrinology and reproductionAbstract
OBJECTIVE: To evaluate the diagnostic additional value of routine alpha-foetoprotein (AFP) assessment in amniotic fluid for the detection of neural tube defects (NTDs), compared with week 20 ultrasonographic examination. DESIGN: Retrospective. METHOD: We retrospectively determined AFP concentrations in amniotic fluid obtained from 7981 women who had undergone amniocentesis for karyotyping and AFP assessment. An AFP concentration greater than 2.5 times the median was considered abnormal. Women were categorised into 4 groups based on the indication for invasive prenatal diagnostic assessment: advanced maternal age (group I; n = 6179), increased risk of foetal NTDs (group II; n = 258), ultrasonographically confirmed foetal NTDs (group III; n = 55) or other indications (group IV; n = 1489). RESULTS: In group I, 18 of 6179 samples had increased AFP levels (0.3%), 2 of which were associated with NTDs. In group II, 2 of 258 samples had increased AFP levels (0.8%); both were associated with NTDs. Increased AFP levels were found in 44 of 55 samples from group III (80%), and 223 of 1489 samples from group IV (15.0%). CONCLUSION: Routine assessment of AFP in amniotic fluid based on advanced maternal age provides little additional value in the detection of NTDs beyond that of week 20 ultrasound.
This item appears in the following Collection(s)
- Academic publications [232297]
- Electronic publications [115548]
- Faculty of Medical Sciences [89118]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.