Conductivity-based hematocrit measurement during cardiopulmonary bypass.
Fulltext:
53595.pdf
Embargo:
until further notice
Size:
229.4Kb
Format:
PDF
Description:
Publisher’s version
Publication year
2007Source
Journal of Clinical Monitoring and Computing, 21, 1, (2007), pp. 7-12ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Health Evidence
Cardiology
Cardio Thoracic Surgery
Former Organization
Epidemiology, Biostatistics & HTA
Thoracic Cardiac Surgery
Journal title
Journal of Clinical Monitoring and Computing
Volume
vol. 21
Issue
iss. 1
Page start
p. 7
Page end
p. 12
Subject
NCEBP 2: Evaluation of complex medical interventions; UMCN 1.5: Interventional oncology; UMCN 2.1: Heart, lung and circulationAbstract
OBJECTIVE: In a recent clinical study on the reliability of a point-of-care (POC) analyzer, we described a downward bias in hematocrit measurement during cardiopulmonary bypass leading potentially to overtreatment with packed red cells. We hypothesized that the detected deviation is caused by variations in electrolyte concentration rather than by colloids used. METHODS: Blood was sampled from patients before cardiac surgery to obtain undiluted anticoagulated whole blood samples (n = 53). From each sample, four dilution series covering a hematocrit range of 15-30% were made using NaCl (0.9%), modified gelatine (4%), hydroxyethylstarch (6%), or a potassium-based (16 mEq/l) solution, respectively. In each dilution series, hematocrit was measured by POC and via the "golden standard" microcentrifugal method to determine whether the deviation of the POC-analyzer to the microcentrifuge was dependent on the type and dilution level of the solution used. RESULTS: In contrast to the colloid-based dilution series, the crystalloids revealed a significant downward bias of the POC-analyzer with respect to the microcentrifuge (p < 0.05). Due to the correction algorithm for sodium in the POC-analyzer, this deviation was nearly constant for NaCl (mean of difference: -1.8 +/- 0.1%), but increased significantly in case of the potassium-based solution (up to -8.2 +/- 0.4% after 1.5-times dilution). The starch- and gelatine-based solutions led to a significant upward bias (p < 0.05) that increased with progressing dilution (up to 1.2 +/- 0.1% for hydroxyethylstarch and up to 1.3 +/- 0.1% for modified gelatine after 1.5-times dilution). CONCLUSIONS: Conductivity-based POC hematocrit measurement suffers from biases due to changes of the plasma constituents. The downward bias in hematocrit as often seen during cardiopulmonary bypass is driven by changes of different electrolyte concentration rather than by colloids used per se.
This item appears in the following Collection(s)
- Academic publications [243859]
- Electronic publications [130610]
- Faculty of Medical Sciences [92795]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.