Spectrophotometric assay for complex I of the respiratory chain in tissue samples and cultured fibroblasts.
Fulltext:
53297.pdf
Embargo:
until further notice
Size:
166.0Kb
Format:
PDF
Description:
Publisher’s version
Publication year
2007Source
Clinical Chemistry, 53, 4, (2007), pp. 729-34ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Paediatrics - OUD tm 2017
Journal title
Clinical Chemistry
Volume
vol. 53
Issue
iss. 4
Page start
p. 729
Page end
p. 34
Subject
IGMD 3: Genomic disorders and inherited multi-system disorders; IGMD 8: Mitochondrial medicine; NCMLS 4: Energy and redox metabolism; ONCOL 3: Translational research; UMCN 5.3: Cellular energy metabolismAbstract
BACKGROUND: A reliable and sensitive complex I assay is an essential tool for the diagnosis of mitochondrial disorders, but current spectrophotometric assays suffer from low sensitivity, low specificity, or both. This deficiency is mainly due to the poor solubility of coenzyme-Q analogs and reaction mixture turbidity caused by the relatively high concentrations of tissue extract that are often required to measure complex I. METHODS: We developed a new spectrophotometric assay to measure complex I in mitochondrial fractions and applied it to muscle and cultured fibroblasts. The method is based on measuring 2,6-dichloroindophenol reduction by electrons accepted from decylubiquinol, reduced after oxidation of NADH by complex I. The assay thus is designed to avoid nonspecific NADH oxidation because electrons produced in these reactions are not accepted by decylubiquinone, resulting in high rotenone sensitivity. RESULTS: The assay was linear with time and amount of mitochondria. The K(m) values for NADH and 2,6-dichloroindophenol in muscle mitochondria were 0.04 and 0.017 mmol/L, respectively. The highest complex I activities were measured with 0.07 mmol/L decylubiquinone and 3.5 g/L bovine serum albumin. The latter was an essential component of the reaction mixture, increasing the solubility of decylubiquinone and rotenone. In patients with previously diagnosed complex I deficiencies, the new assay detected the complex I deficiencies in both muscle and fibroblasts. CONCLUSIONS: This spectrophotometric assay is reproducible, sensitive, and specific for complex I activity because of its high rotenone sensitivity, and it can be applied successfully to the diagnosis of complex I deficiencies.
This item appears in the following Collection(s)
- Academic publications [244084]
- Electronic publications [131085]
- Faculty of Medical Sciences [92872]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.