The time-resolved fluorescence-based PCA3 test on urinary sediments after digital rectal examination; a Dutch multicenter validation of the diagnostic performance.
Fulltext:
52738.pdf
Embargo:
until further notice
Size:
201.4Kb
Format:
PDF
Description:
Publisher’s version
Publication year
2007Source
Clinical Cancer Research, 13, 3, (2007), pp. 939-43ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Urology
Journal title
Clinical Cancer Research
Volume
vol. 13
Issue
iss. 3
Page start
p. 939
Page end
p. 43
Subject
NCEBP 1: Molecular epidemiology; NCMLS 6: Genetics and epigenetic pathways of disease; ONCOL 1: Hereditary cancer and cancer-related syndromes; ONCOL 3: Translational research; ONCOL 5: Aetiology, screening and detection; UMCN 1.1: Functional ImagingAbstract
PURPOSE: To improve the specificity in prostate cancer diagnosis and to prevent unnecessary prostate biopsies, especially in the serum prostate-specific antigen (PSA) "gray zone" between 3 and 15 ng/mL, the implementation of prostate cancer-specific markers is urgently needed. The recently discovered prostate cancer antigen 3 (PCA3) is such a promising prostate cancer marker. In a previous single institution study, the PCA3 urine test clearly proved to be of diagnostic value. Therefore, the diagnostic performance of the PCA3 urine test was validated in a multicenter study. EXPERIMENTAL DESIGN: The first voided urine after digital rectal examination was collected from a total of 583 men with serum PSA levels between 3 and 15 ng/mL who were to undergo prostate biopsies. We determined the PCA3 score in these samples and correlated the results with the results of the prostate biopsies. RESULTS: A total of 534 men (92%) had an informative sample. The area under the receiver-operating characteristic curve, a measure of the diagnostic accuracy of a test, was 0.66 for the PCA3 urine test and 0.57 for serum PSA. The sensitivity for the PCA3 urine test was 65%, the specificity was 66% (versus 47% for serum PSA), and the negative predictive value was 80%. CONCLUSIONS: In this multicenter study, we validated the diagnostic performance of the PCA3 urine test in the largest group studied thus far using a PCA3 gene-based test. This study shows that the PCA3 urine test, when used as a reflex test, can improve the specificity in prostate cancer diagnosis and could prevent many unnecessary prostate biopsies.
This item appears in the following Collection(s)
- Academic publications [242560]
- Electronic publications [129511]
- Faculty of Medical Sciences [92283]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.