Fulltext:
47695.pdf
Embargo:
until further notice
Size:
85.80Kb
Format:
PDF
Description:
Publisher’s version
Publication year
2005Source
World Journal of Surgery, 29, 4, (2005), pp. 441-5ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Surgery
Journal title
World Journal of Surgery
Volume
vol. 29
Issue
iss. 4
Page start
p. 441
Page end
p. 5
Subject
N4i 1: Pathogenesis and modulation of inflammation; UMCN 4.3: Tissue engineering and reconstructive surgeryAbstract
Glove perforation frequently occurs during the course of surgical procedures, introducing risks for both surgeons and patients. The aim of this study was to compare the use of blunt tapered and "sharp" needles during abdominal wall closure with respect to the incidence of glove perforation and the convenience of needle handling. A series of 200 patients undergoing laparotomy in a 6-month period for general surgical disorders were randomized to two groups; in one, the abdominal fascia was closed with a blunt tapered needle; in the other, a sharp needle was used. The main outcome measures were glove perforation and convenience of handling the needle. Univariate and multivariate analyses were performed. In all, 56 glove perforations occurred during 40 (20%) surgical procedures. Perforation rates differed significantly: 12% for the blunt (n = 100) tapered needle and 28% (n = 100) for the sharp needle (p = 0.003). Only in 12 cases (21%) was the glove perforation detected at surgery. The type of needle (odds ratio 0.35, p = 0.006) and time taken to close the fascia (odds ratio 1.001, p = 0.05) significantly affected the risk of glove perforation. At multivariate logistic regression analysis the type of needle (odds ratio 0.23, p = 0.004) and the visual analog linear scale (VAS) for ease of needle handling (odds ratio 1.18, p = 0.019) were important predictive factors for glove perforation. With the blunt tapered needle, the VAS was significantly (p = 0.0003) higher at primary laparotomy than at relaparotomy. Use of the blunt tapered needle reduces the incidence of glove perforation. Laborious closure predicts glove perforation. Blunt tapered needles are less convenient in closing a scarred abdominal fascia.
This item appears in the following Collection(s)
- Academic publications [246764]
- Electronic publications [134205]
- Faculty of Medical Sciences [93461]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.