Traditional biomolecular structure determination by NMR spectroscopy allows for major errors
Publication year
2006Source
Plos Computational Biology, 2, 2, (2006), pp. 0071-0079, article e9ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Bioinformatics
Bio-organic Chemistry
CMBI
Former Organization
Physical Chemistry/Biophysical Chemistry
Journal title
Plos Computational Biology
Volume
vol. 2
Issue
iss. 2
Page start
p. 0071
Page end
p. 0079
Subject
Bioinformatics; Biophysical Chemistry; NCMLS 7: Chemical and physical biology; UMCN 5.3: Cellular energy metabolismAbstract
One of the major goals of structural genomics projects is to determine the three-dimensional structure of representative members of as many different fold families as possible. Comparative modeling is expected to fill the remaining gaps by providing structural models of homologs of the experimentally determined proteins. However, for such an approach to be successful it is essential that the quality of the experimentally determined structures is adequate. In an attempt to build a homology model for the protein dynein light chain 2A (DLC2A) we found two potential templates, both experimentally determined nuclear magnetic resonance (NMR) structures originating from structural genomics efforts. Despite their high sequence identity (96%), the folds of the two structures are markedly different. This urged us to perform in-depth analyses of both structure ensembles and the deposited experimental data, the results of which clearly identify one of the two models as largely incorrect. Next, we analyzed the quality of a large set of recent NMR-derived structure ensembles originating from both structural genomics projects and individual structure determination groups. Unfortunately, a visual inspection of structures exhibiting lower quality scores than DLC2A reveals that the seriously flawed DLC2A structure is not an isolated incident. Overall, our results illustrate that the quality of NMR structures cannot be reliably evaluated using only traditional experimental input data and overall quality indicators as a reference and clearly demonstrate the urgent need for a tight integration of more sophisticated structure validation tools in NMR structure determination projects. In contrast to common methodologies where structures are typically evaluated as a whole, such tools should preferentially operate on a per-residue basis.
This item appears in the following Collection(s)
- Academic publications [243908]
- Electronic publications [130674]
- Faculty of Medical Sciences [92803]
- Faculty of Science [36924]
- Open Access publications [104963]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.