Development and validation of an UPLC-MS/MS assay for the simultaneous quantification of seven commonly used antibiotics in human plasma and its application in therapeutic drug monitoring
Publication year
2024Source
Journal of Antimicrobial Chemotherapy, 79, 4, (2024), pp. 883-890ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Clinical Pharmacy
Pharmacy
Journal title
Journal of Antimicrobial Chemotherapy
Volume
vol. 79
Issue
iss. 4
Page start
p. 883
Page end
p. 890
Subject
Pharmacy - Radboud University Medical CenterAbstract
OBJECTIVE: To develop and validate an UPLC-MS/MS assay for simultaneous determination of the total concentration of ceftazidime, ciprofloxacin, flucloxacillin, piperacillin, tazobactam, sulfamethoxazole, N-acetyl sulfamethoxazole and trimethoprim, and the protein-unbound concentration of flucloxacillin, in human plasma to be used for research and clinical practice. METHODS: Sample pretreatment included protein precipitation with methanol. For the measurement of protein-unbound flucloxacillin, ultrafiltration was performed at physiological temperature. For all compounds, a stable isotopically labelled internal standard was used. Reliability of the results was assessed by participation in an international quality control programme. RESULTS: The assay was successfully validated according to the EMA guidelines over a concentration range of 0.5-100 mg/L for ceftazidime, 0.05-10 mg/L for ciprofloxacin, 0.4-125 mg/L for flucloxacillin, 0.2-60 mg/L for piperacillin, 0.15-30 mg/L for tazobactam, 1-200 mg/L for sulfamethoxazole and N-acetyl sulfamethoxazole, 0.05-10 mg/L for trimethoprim and 0.10-50 mg/L for unbound flucloxacillin. For measurement of total concentrations, the within- and between-day accuracy ranged from 90.0% to 109%, and 93.4% to 108%, respectively. Within- and between-day precision (variation coefficients, CVs) ranged from 1.70% to 11.2%, and 0.290% to 5.30%, respectively. For unbound flucloxacillin, within-day accuracy ranged from 103% to 106% and between-day accuracy from 102% to 105%. The within- and between-day CVs ranged from 1.92% to 7.11%. Results of the international quality control programme showed that the assay is reliable. CONCLUSIONS: The method provided reliable, precise and accurate measurement of seven commonly prescribed antibiotics, including the unbound concentration of flucloxacillin. This method is now routinely applied in research and clinical practice.
This item appears in the following Collection(s)
- Academic publications [242524]
- Electronic publications [129515]
- Faculty of Medical Sciences [92283]
- Open Access publications [104134]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.