Performance of a consensus-based algorithm for diagnosing anastomotic leak after minimally invasive esophagectomy for esophageal cancer.
Publication year
2023Source
Diseases of the Esophagus, 36, 10, (2023), pp. doad016, article doad016ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Surgery
Medical Imaging
Journal title
Diseases of the Esophagus
Volume
vol. 36
Issue
iss. 10
Page start
p. doad016
Subject
Radboudumc 10: Reconstructive and regenerative medicine Medical Imaging; Radboudumc 14: Tumours of the digestive tract Surgery; Radboud University Medical CenterAbstract
Anastomotic leak (AL) is a common and severe complication after esophagectomy. This study aimed to assess the performance of a consensus-based algorithm for diagnosing AL after minimally invasive esophagectomy. This study used data of the ICAN trial, a multicenter randomized clinical trial comparing cervical and intrathoracic anastomosis, in which a predefined diagnostic algorithm was used to guide diagnosing AL. The algorithm identified patients suspected of AL based on clinical signs, blood C-reactive protein (cut-off value 200 mg/L), and/or drain amylase (cut-off value 200 IU/L). Suspicion of AL prompted evaluation with contrast swallow computed tomography and/or endoscopy to confirm AL. Primary outcome measure was algorithm performance in terms of sensitivity, specificity, and positive and negative predictive values (PPV, NPV), respectively. AL was defined according to the definition of the Esophagectomy Complications Consensus Group. 245 patients were included, and 125 (51%) patients were suspected of AL. The algorithm had a sensitivity of 62% (95% confidence interval [CI]: 46-75), a specificity of 97% (95% CI: 89-100), and a PPV and NPV of 94% (95% CI: 79-99) and 77% (95% CI: 66-86), respectively, on initial assessment. Repeated assessment in 19 patients with persisting suspicion of AL despite negative or inconclusive initial assessment had a sensitivity of 100% (95% CI: 77-100). The algorithm showed poor performance because the low sensitivity indicates the inability of the algorithm to confirm AL on initial assessment. Repeated assessment using the algorithm was needed to confirm remaining leaks.
This item appears in the following Collection(s)
- Academic publications [246515]
- Electronic publications [134102]
- Faculty of Medical Sciences [93308]
- Open Access publications [107633]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.