Accuracy of thin-slice model-based iterative reconstruction designed for brain CT to diagnose acute ischemic stroke in the middle cerebral artery territory: a multicenter study.

Fulltext:
246121.pdf
Embargo:
until further notice
Size:
1.288Mb
Format:
PDF
Description:
Publisher’s version
Publication year
2021Source
Neuroradiology, 63, 12, (2021), pp. 2013-2021ISSN
Annotation
01 december 2021
Publication type
Article / Letter to editor

Display more detailsDisplay less details
Organization
Medical Imaging
Journal title
Neuroradiology
Volume
vol. 63
Issue
iss. 12
Page start
p. 2013
Page end
p. 2021
Subject
Radboudumc 15: Urological cancers RIHS: Radboud Institute for Health Sciences; Radboudumc 16: Vascular damage RIHS: Radboud Institute for Health SciencesAbstract
PURPOSE: Model-based iterative reconstruction (MBIR) yields higher spatial resolution and a lower image noise than conventional reconstruction methods. We hypothesized that thin-slice MBIR designed for brain CT could improve the detectability of acute ischemic stroke in the middle cerebral artery (MCA) territory. METHODS: Included were 41 patients with acute ischemic stroke in the MCA territory; they were seen at 4 medical centers. The controls were 39 subjects without acute stroke. Images were reconstructed with hybrid IR and with MBIR designed for brain CT at slice thickness of 2 mm. We measured the image noise in the ventricle and compared the contrast-to-noise ratio (CNR) in the ischemic lesion. We analyzed the ability of reconstructed images to detect ischemic lesions using receiver operating characteristics (ROC) analysis; 8 observers read the routine clinical hybrid IR with 5 mm-thick images, while referring to 2 mm-thick hybrid IR images or MBIR images. RESULTS: The image noise was significantly lower on MBIR- than hybrid IR images (1.2 vs. 3.4, p < 0.001). The CNR was significantly higher with MBIR than hybrid IR (6.3 vs. 1.6, p < 0.001). The mean area under the ROC curve was also significantly higher on hybrid IR plus MBIR than hybrid IR (0.55 vs. 0.48, p < 0.036). Sensitivity, specificity, and accuracy were 41.2%, 88.8%, and 65.7%, respectively, for hybrid IR; they were 58.8%, 86.1%, and 72.9%, respectively, for hybrid IR plus MBIR. CONCLUSION: The additional thin-slice MBIR designed for brain CT may improve the detection of acute MCA stroke.
This item appears in the following Collection(s)
- Academic publications [229074]
- Electronic publications [111477]
- Faculty of Medical Sciences [87745]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.