Publication year
2021Source
Physics in Medicine and Biology, 66, 8, (2021), article 085010ISSN
Publication type
Article / Letter to editor

Display more detailsDisplay less details
Organization
Radiation Oncology
Journal title
Physics in Medicine and Biology
Volume
vol. 66
Issue
iss. 8
Subject
Radboudumc 14: Tumours of the digestive tract RIHS: Radboud Institute for Health SciencesAbstract
A synthetic computed tomography (sCT) is required for daily plan optimization on an MRI-linac. Yet, only limited information is available on the accuracy of dose calculations on sCT for breast radiotherapy. This work aimed to (1) evaluate dosimetric accuracy of treatment plans for single-fraction neoadjuvant partial breast irradiation (PBI) on a 1.5 T MRI-linac calculated on a) bulk-density sCT mimicking the current MRI-linac workflow and b) deep learning-generated sCT, and (2) investigate the number of bulk-density levels required. For ten breast cancer patients we created three bulk-density sCTs of increasing complexity from the planning-CT, using bulk-density for: (1) body, lungs, and GTV (sCT(BD1)); (2) volumes for sCT(BD1)plus chest wall and ipsilateral breast (sCT(BD2)); (3) volumes for sCT(BD2)plus ribs (sCT(BD3)); and a deep learning-generated sCT (sCT(DL)) from a 1.5 T MRI in supine position. Single-fraction neoadjuvant PBI treatment plans for a 1.5 T MRI-linac were optimized on each sCT and recalculated on the planning-CT. Image evaluation was performed by assessing mean absolute error (MAE) and mean error (ME) in Hounsfield Units (HU) between the sCTs and the planning-CT. Dosimetric evaluation was performed by assessing dose differences, gamma pass rates, and dose-volume histogram (DVH) differences. The following results were obtained (median across patients for sCT(BD1)/sCT(BD2)/sCT(BD3)/sCT(DL)respectively): MAE inside the body contour was 106/104/104/75 HU and ME was 8/9/6/28 HU, mean dose difference in the PTV(GTV)was 0.15/0.00/0.00/-0.07 Gy, median gamma pass rate (2%/2 mm, 10% dose threshold) was 98.9/98.9/98.7/99.4%, and differences in DVH parameters were well below 2% for all structures except for the skin in the sCT(DL). Accurate dose calculations for single-fraction neoadjuvant PBI on an MRI-linac could be performed on both bulk-density and deep learning sCT, facilitating further implementation of MRI-guided radiotherapy for breast cancer. Balancing simplicity and accuracy, sCT(BD2)showed the optimal number of bulk-density levels for a bulk-density approach.
This item appears in the following Collection(s)
- Academic publications [227693]
- Faculty of Medical Sciences [86198]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.