The datasets contain all raw data and edited data used for analyses in the research "The STArgardt Remofuscin Treatment Trial (STARTT)".
ABSTRACT
Background
This report describes the study design and baseline characteristics of patients with Stargardt disease (STGD1) enrolled in the STArgardt Remofuscin Treatment Trial (STARTT), EudraCT No. 2018-001496-20.
Methods
A total of 87 patients with genetically confirmed STGD1 were randomized in a double-masked, placebo-controlled proof of concept trial to evaluate the safety and efficacy of 20 milligram oral Remofuscin for 24 months. The primary outcome measure is the change in mean quantitative autofluorescence value of an 8-segment ring centred on the fovea (qAF8). Secondary efficacy variables are best corrected visual acuity (BCVA), low-luminance visual acuity (LLVA), mesopic microperimetry (mMP), SD-OCT, reading speed on Radner reading charts, and patient-reported visual function as assessed by the National Eye Institute Visual Functioning Questionnaire 25 (NEI VFQ-25) and Functional Reading Independence (FRI) Index.
Results
Mean age of the participants was 35±11 years and 49 (56%) were female. Median qAF8 value was 438 Units (range 210-729). Median BCVA and LLVA in decimal units were 0.50 (range 0.13-0.80) and 0.20 (range 0.06-0.63) respectively. The median of the mean retinal sensitivity with mMP was 20.4 dB (range 0.0-28.8). SD-OCT showed a median central subfield retinal thickness of 142 µm (range 72-265) and a median macular volume of 1.65 mm3 (range 1.13-2.19). Compared to persons without vision impairment, both reading performance and patient-reported visual function were significantly lower (p<0.001, one sample t-test). Mean reading speed was 108±39 words/minute with logRAD-score of 0.45±0.28. Mean VFQ-25 composite score was 72±13. Mean FRI Index score 2.8±0.6.
Conclusions
This trial design may serve as reference for future clinical trials as it explores the utility of qAF8 as primary outcome measure. The baseline data represent the largest, multi-national, STGD1 cohort to date that underwent standardized qAF imaging, reading speed assessment and vision-related quality of life measures which all contribute to the characterization of STGD1.