Evaluation of a deep learning system for the joint automated detection of diabetic retinopathy and age-related macular degeneration
Publication year
2020Source
Acta Ophthalmologica (2008), 98, 4, (2020), pp. 368-377ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Medical Imaging
Ophthalmology
Journal title
Acta Ophthalmologica (2008)
Volume
vol. 98
Issue
iss. 4
Page start
p. 368
Page end
p. 377
Subject
Radboudumc 12: Sensory disorders DCMN: Donders Center for Medical Neuroscience; Radboudumc 9: Rare cancers RIHS: Radboud Institute for Health Sciences; Medical Imaging - Radboud University Medical Center; Ophthalmology - Radboud University Medical CenterAbstract
PURPOSE: To validate the performance of a commercially available, CE-certified deep learning (DL) system, RetCAD v.1.3.0 (Thirona, Nijmegen, The Netherlands), for the joint automatic detection of diabetic retinopathy (DR) and age-related macular degeneration (AMD) in colour fundus (CF) images on a dataset with mixed presence of eye diseases. METHODS: Evaluation of joint detection of referable DR and AMD was performed on a DR-AMD dataset with 600 images acquired during routine clinical practice, containing referable and non-referable cases of both diseases. Each image was graded for DR and AMD by an experienced ophthalmologist to establish the reference standard (RS), and by four independent observers for comparison with human performance. Validation was furtherly assessed on Messidor (1200 images) for individual identification of referable DR, and the Age-Related Eye Disease Study (AREDS) dataset (133 821 images) for referable AMD, against the corresponding RS. RESULTS: Regarding joint validation on the DR-AMD dataset, the system achieved an area under the ROC curve (AUC) of 95.1% for detection of referable DR (SE = 90.1%, SP = 90.6%). For referable AMD, the AUC was 94.9% (SE = 91.8%, SP = 87.5%). Average human performance for DR was SE = 61.5% and SP = 97.8%; for AMD, SE = 76.5% and SP = 96.1%. Regarding detection of referable DR in Messidor, AUC was 97.5% (SE = 92.0%, SP = 92.1%); for referable AMD in AREDS, AUC was 92.7% (SE = 85.8%, SP = 86.0%). CONCLUSION: The validated system performs comparably to human experts at simultaneous detection of DR and AMD. This shows that DL systems can facilitate access to joint screening of eye diseases and become a quick and reliable support for ophthalmological experts.
This item appears in the following Collection(s)
- Academic publications [246425]
- Electronic publications [134061]
- Faculty of Medical Sciences [93307]
- Open Access publications [107626]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.