A quality control system for ligand-binding assay of plasma renin activity: Proof-of-concept within a pharmacodynamic study
Fulltext:
220641.pdf
Embargo:
until further notice
Size:
1.426Mb
Format:
PDF
Description:
Publisher’s version
Publication year
2020Source
Journal of Pharmaceutical and Biomedical Analysis, 181, (2020), article 113090ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Pharmacology-Toxicology
Intensive Care
Journal title
Journal of Pharmaceutical and Biomedical Analysis
Volume
vol. 181
Subject
Radboudumc 11: Renal disorders RIHS: Radboud Institute for Health Sciences; Intensive Care - Radboud University Medical Center; Pharmacology-Toxicology - Radboud University Medical CenterAbstract
While the role of plasma renin activity (PRA) in heart failure has been widely studied in adults, comprehensive data on pediatric heart failure remain lacking. This drawback is increasingly being addressed by academic research. Nevertheless, such pediatric investigations are commonly conducted only once due to ethical constraints. Therefore, the quality of bioanalytical data must be ensured to acquire meaningful insights into maturing humoral parameters. However, appropriate post-validation assessment of bioanalytical runs is currently underrepresented by regulatory guidance. Thus, for applications in an academic environment, an easy-to-handle six-step bioanalytical quality control system was designed based on regulatory guidelines (e.g. U.S. Food and Drug Administration) combined with international recommendations (e.g. Clinical and Laboratory Standards Institute) and current scientific discussion. Its applicability to an enzyme-linked immunosorbent assay for determination of PRA was investigated within three pediatric trials of the EU-funded "Labeling of Enalapril in Neonates up to Adolescents" project. This quality control system identified 15 % bioanalytical runs as non-compliant to the predefined specifications and ensured the reliable quantification of 940 pharmacodynamic samples. The inter-run assessment of quality controls was able to demonstrate the comparability of the study results. Furthermore, 86 % of incurred sample reanalysis pairs complied with regulatory requirements (>67 %), thus underlining the long-term reproducibility of the utilized ligand-binding assay. Successful participation in interlaboratory testing confirmed the accuracy of the applied method throughout the entire study period. Further investigations showed no notable differences between the five applied lots of the PRA assay. The applicability of this quality control system was proven in an academic environment and ensured reliable results for PRA over the entire 24-month study period.
This item appears in the following Collection(s)
- Academic publications [246625]
- Electronic publications [134196]
- Faculty of Medical Sciences [93367]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.