Navvus FFR to reduce CONTRAst, Cost and radiaTion (CONTRACT); insights from a single-centre clinical and economical evaluation with the RXi Rapid-Exchange FFR device
Fulltext:
182626.pdf
Embargo:
until further notice
Size:
365.3Kb
Format:
PDF
Description:
Publisher’s version
Publication year
2017Source
International Journal of Cardiology, 233, (2017), pp. 80-84ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Cardiology
Journal title
International Journal of Cardiology
Volume
vol. 233
Page start
p. 80
Page end
p. 84
Subject
Radboudumc 16: Vascular damage RIHS: Radboud Institute for Health Sciences; Cardiology - Radboud University Medical CenterAbstract
OBJECTIVES: To assess whether the RXi Navvus system compared to the use of standard Fractional Flow Reserve (FFR) wires reduces total contrast volume, radiation and overall study cost in a real world patient population referred for coronary angiography or percutaneous coronary intervention. BACKGROUND: FFR is the mainstay of functional hemodynamic assessment of coronary artery lesions. The RXi Navvus system (ACIST Medical Systems, Eden Prairie, MN) is a monorail microcatheter with FFR-measurement capability through optical pressure sensor technology. METHODS: This is an investigator-initiated, prospective, single-center, observational cohort study. A total of 238 patients were enrolled, 97 patients with Navvus and 141 with conventional pressure-wire based FFR (PW-FFR). Final analyses were performed on the cohort in which only 1 device was used (82 Navvus procedures vs. 136 PW-FFR procedures). RESULTS: No significant differences were found in the total amount of contrast used (150+/-77 vs 147+/-79ml; p=0.81), radiation use (6200+/-4601 vs. 5076+/-4655 centiG *cm(2); p=0.09) or costs (euro1994,- vs. euro1930,-; p=0.32) in the Navvus vs. PW-FFR groups respectively. CONCLUSIONS: No significant differences were found in the amount of contrast used, total procedural costs or radiation when the Navvus system was used as compared to conventional FFR wires. CONDENSED ABSTRACT: CONTRACT is an investigator-initiated, prospective, single-center, observational cohort study that evaluated whether the RXi Navvus system compared to the use of standard Fractional Flow Reserve (FFR) wires reduces total contrast volume, radiation and overall study cost in a real world patient population referred for coronary angiography or percutaneous coronary intervention. Use of the RXi Navvus system was associated with comparable procedural costs, amount of radiation and contrast used as compared to PW-FFR systems.
This item appears in the following Collection(s)
- Academic publications [244228]
- Electronic publications [131195]
- Faculty of Medical Sciences [92893]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.