Fast interactive segmentation of the pulmonary lobes from thoracic computed tomography data
Publication year
2017Source
Physics in Medicine and Biology, 62, 16, (2017), pp. 6649-6665ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Medical Imaging
Journal title
Physics in Medicine and Biology
Volume
vol. 62
Issue
iss. 16
Page start
p. 6649
Page end
p. 6665
Subject
Radboudumc 5: Inflammatory diseases RIHS: Radboud Institute for Health Sciences; Radboudumc 9: Rare cancers RIHS: Radboud Institute for Health Sciences; Medical Imaging - Radboud University Medical CenterAbstract
Automated lung lobe segmentation methods often fail for challenging and clinically relevant cases with incomplete fissures or substantial amounts of pathology. We present a fast and intuitive method to interactively correct a given lung lobe segmentation or to quickly create a lobe segmentation from scratch based on a lung mask. A given lobar boundary is converted into a mesh by principal component analysis of 3D lobar boundary markers to obtain a plane where nodes correspond to the position of the markers. An observer can modify the mesh by drawing on 2D slices in arbitrary orientations. After each drawing, the mesh is immediately adapted in a 3D region around the user interaction. For evaluation we participated in the international lung lobe segmentation challenge LObe and Lung Analysis 2011 (LOLA11). Two observers applied the method to correct a given lung lobe segmentation obtained by a fully automatic method for all 55 CT scans of LOLA11. On average observer 1/2 required 8+-4/25+-12 interactions per case and took 1:30+-0:34/3:19+-1:29 min. The average distances to the reference segmentation were improved from an initial 2.68+-14.71 mm to 0.89+-1.63/0.74+-1.51 mm. In addition, one observer applied the proposed method to create a segmentation from scratch. This took 3:44+-0:58 minutes on average per case, applying an average of 20+-3 interactions to reach an average distance to the reference of 0.77+-1.14 mm. Thus, both the interactive corrections and the creation of a segmentation from scratch were feasible in a short time with excellent results and minimal interaction. Since the mesh adaptation is independent of image features, the method can successfully handle patients with severe pathologies, provided that the human operator is capable of correctly indicating the lobar boundaries.
This item appears in the following Collection(s)
- Academic publications [248274]
- Electronic publications [135674]
- Faculty of Medical Sciences [94130]
- Open Access publications [108952]
Upload full text
Use your RU or RadboudUMC credentials to log in with SURFconext to upload a file for processing by the repository team.