Publication year
2001Source
Clinical Neurophysiology, 112, 4, (2001), pp. 713--9ISSN
Publication type
Article / Letter to editor

Display more detailsDisplay less details
Organization
Cognitive Neuroscience
Neurology
Journal title
Clinical Neurophysiology
Volume
vol. 112
Issue
iss. 4
Page start
p. 713-
Page end
p. 9
Subject
Brain and Behaviour / Bioelectricity; Pathophysiology of Brain and Behaviour; Hersenen en Gedrag / Bio-elektriciteit; Pathofysiologie van Hersenen en GedragAbstract
OBJECTIVE: A system for electrode placement is described. It is designed for studies on topography and source analysis of spontaneous and evoked EEG activity. METHOD: The proposed system is based on the extended International 10-20 system which contains 74 electrodes, and extends this system up to 345 electrode locations. RESULTS: The positioning and nomenclature of the electrode system is described, and a subset of locations is proposed as especially useful for modern EEG/ERP systems, often having 128 channels available. CONCLUSION: Similar to the extension of the 10-20 system to the 10-10 system ("10% system"), proposed in 1985, the goal of this new extension to a 10-5 system is to further promote standardization in high-resolution EEG studies.
This item appears in the following Collection(s)
- Academic publications [227695]
- Faculty of Medical Sciences [87091]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.