Percutaneous MR Imaging-Guided Cryoablation of Small Renal Masses in a 3-T Closed-Bore MR Imaging Environment: Initial Experience

Fulltext:
177869.pdf
Embargo:
until further notice
Size:
1023.Kb
Format:
PDF
Description:
Publisher’s version
Publication year
2017Source
Journal of Vascular and Interventional Radiology, 28, 8, (2017), pp. 1098-1107 e1ISSN
Publication type
Article / Letter to editor

Display more detailsDisplay less details
Organization
Medical Imaging
Urology
Journal title
Journal of Vascular and Interventional Radiology
Volume
vol. 28
Issue
iss. 8
Page start
p. 1098
Page end
p. 1107 e1
Subject
Radboudumc 0: Other Research RIHS: Radboud Institute for Health Sciences; Radboudumc 15: Urological cancers RIHS: Radboud Institute for Health Sciences; Radboudumc 15: Urological cancers RIMLS: Radboud Institute for Molecular Life SciencesAbstract
PURPOSE: To assess the feasibility of percutaneous magnetic resonance (MR) imaging-guided cryoablation of small renal masses (SRMs) in a 3-T environment and to evaluate intraprocedural imaging, procedural safety, and initial outcomes. MATERIALS AND METHODS: The analysis included 9 patients (4 men; median age, 72 y; range, 70-82 y) with 9 SRMs (diameter, 12-30 mm). Lesions underwent biopsy, and cryoneedles were inserted under ultrasound guidance. Verification of needle positions and ice-ball monitoring were performed by T1-weighted volumetric interpolated breath-hold examination and T2-weighted half-Fourier acquired single-shot turbo spin-echo sequences. On image analysis, needle positioning was considered appropriate if the target lesion border was visible, the needle tip was inside the target lesion, and the ice ball was expected to cover the target lesion with a 5-mm margin. If these criteria could not be assessed, imaging was considered inadequate. Technical success was defined as tumor coverage with a 5-mm margin and no residual disease on 1-mo follow-up MR imaging. RESULTS: Median total procedure time was 170 min (range, 135-193 min). Intraoperative imaging allowed adequate needle visualization in 67% of acquired scans (4 of 7 T1-weighted and 6 of 8 T2-weighted). Appropriate positioning of two or three needles used for each procedure was confirmed in all cases on T1- or T2-weighted imaging. Ice-ball formation was adequately visualized in all patients. Technical success rate was 100%. No local recurrences were detected on follow-up imaging at a median of 12 mo (range, 3-22 mo). CONCLUSIONS: Percutaneous MR-guided cryoablation of SRMs in a 3-T MR imaging environment is safe and feasible, showing adequate intraoperative imaging capabilities with promising short-term clinical outcomes.
This item appears in the following Collection(s)
- Academic publications [226841]
- Electronic publications [108452]
- Faculty of Medical Sciences [86405]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.