Continuous Monitoring of Vital Signs Using Wearable Devices on the General Ward: Pilot Study
Publication year
2017Source
JMIR mHealth and uHealth, 5, 7, (2017), pp. e91ISSN
Publication type
Article / Letter to editor

Display more detailsDisplay less details
Organization
Surgery
Internal Medicine
Journal title
JMIR mHealth and uHealth
Volume
vol. 5
Issue
iss. 7
Page start
p. e91
Subject
Radboudumc 10: Reconstructive and regenerative medicine RIHS: Radboud Institute for Health Sciences; Radboudumc 10: Reconstructive and regenerative medicine RIMLS: Radboud Institute for Molecular Life Sciences; Radboudumc 14: Tumours of the digestive tract RIHS: Radboud Institute for Health Sciences; Radboudumc 16: Vascular damage RIHS: Radboud Institute for Health SciencesAbstract
BACKGROUND: Measurement of vital signs in hospitalized patients is necessary to assess the clinical situation of the patient. Early warning scores (EWS), such as the modified early warning score (MEWS), are generally calculated 3 times a day, but these may not capture early deterioration. A delay in diagnosing deterioration is associated with increased mortality. Continuous monitoring with wearable devices might detect clinical deterioration at an earlier stage, which allows clinicians to take corrective actions. OBJECTIVE: In this pilot study, the feasibility of continuous monitoring using the ViSi Mobile (VM; Sotera Wireless) and HealthPatch (HP; Vital Connect) was tested, and the experiences of patients and nurses were collected. METHODS: In this feasibility study, 20 patients at the internal medicine and surgical ward were monitored with VM and HP simultaneously for 2 to 3 days. Technical problems were analyzed. Vital sign measurements by nurses were taken as reference and compared with vital signs measured by both devices. Patient and nurse experiences were obtained by semistructured interviews. RESULTS: In total, 86 out of 120 MEWS measurements were used for the analysis. Vital sign measurements by VM and HP were generally consistent with nurse measurements. In 15% (N=13) and 27% (N=23) of the VM and HP cases respectively, clinically relevant differences in MEWS were found based on inconsistent respiratory rate registrations. Connection failure was recognized as a predominant VM artifact (70%). Over 50% of all HP artifacts had an unknown cause, were self-limiting, and never took longer than 1 hour. The majority of patients, relatives, and nurses were positive about VM and HP. CONCLUSIONS: Both VM and HP are promising for continuously monitoring vital signs in hospitalized patients, if the frequency and duration of artifacts are reduced. The devices were well received and comfortable for most patients.
This item appears in the following Collection(s)
- Academic publications [227244]
- Electronic publications [108520]
- Faculty of Medical Sciences [86731]
- Open Access publications [77772]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.