Interobserver delineation uncertainty in involved-node radiation therapy (INRT) for early-stage Hodgkin lymphoma: on behalf of the Radiotherapy Committee of the EORTC lymphoma group
Publication year
2017Source
Acta Oncologica, 56, 4, (2017), pp. 608-613ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Radiation Oncology
Journal title
Acta Oncologica
Volume
vol. 56
Issue
iss. 4
Page start
p. 608
Page end
p. 613
Subject
Radboudumc 9: Rare cancers RIHS: Radboud Institute for Health Sciences; Radiation Oncology Radboud University Medical CenterAbstract
BACKGROUND AND PURPOSE: In early-stage classical Hodgkin lymphoma (HL) the target volume nowadays consists of the volume of the originally involved nodes. Delineation of this volume on a post-chemotherapy CT-scan is challenging. We report on the interobserver variability in target volume definition and its impact on resulting treatment plans. MATERIALS AND METHODS: Two representative cases were selected (1: male, stage IB, localization: left axilla; 2: female, stage IIB, localizations: mediastinum and bilateral neck). Eight experienced observers individually defined the clinical target volume (CTV) using involved-node radiotherapy (INRT) as defined by the EORTC-GELA guidelines for the H10 trial. A consensus contour was generated and the standard deviation computed. We investigated the overlap between observer and consensus contour [Sorensen-Dice coefficient (DSC)] and the magnitude of gross deviations between the surfaces of the observer and consensus contour (Hausdorff distance). 3D-conformal (3D-CRT) and intensity-modulated radiotherapy (IMRT) plans were calculated for each contour in order to investigate the impact of interobserver variability on each treatment modality. Similar target coverage was enforced for all plans. RESULTS: The median CTV was 120 cm3 (IQR: 95-173 cm3) for Case 1, and 255 cm3 (IQR: 183-293 cm3) for Case 2. DSC values were generally high (>0.7), and Hausdorff distances were about 30 mm. The SDs between all observer contours, providing an estimate of the systematic error associated with delineation uncertainty, ranged from 1.9 to 3.8 mm (median: 3.2 mm). Variations in mean dose resulting from different observer contours were small and were not higher in IMRT plans than in 3D-CRT plans. CONCLUSIONS: We observed considerable differences in target volume delineation, but the systematic delineation uncertainty of around 3 mm is comparable to that reported in other tumour sites. This report is a first step towards calculating an evidence-based planning target volume margin for INRT in HL.
This item appears in the following Collection(s)
- Academic publications [243984]
- Electronic publications [130695]
- Faculty of Medical Sciences [92811]
- Open Access publications [104970]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.