Estimation of extravascular lung water using the transpulmonary ultrasound dilution (TPUD) method: a validation study in neonatal lambs
Publication year
2016Source
Journal of Clinical Monitoring and Computing, 30, 6, (2016), pp. 985-994ISSN
Publication type
Article / Letter to editor

Display more detailsDisplay less details
Organization
Paediatrics - OUD tm 2017
Intensive Care
Medical Imaging
Journal title
Journal of Clinical Monitoring and Computing
Volume
vol. 30
Issue
iss. 6
Page start
p. 985
Page end
p. 994
Subject
Radboudumc 16: Vascular damage RIHS: Radboud Institute for Health Sciences; Radboudumc 18: Healthcare improvement science RIHS: Radboud Institute for Health Sciences; Radboudumc 4: lnfectious Diseases and Global Health RIHS: Radboud Institute for Health SciencesAbstract
Increased extravascular lung water (EVLW) may contribute to respiratory failure in neonates. Accurate measurement of EVLW in these patients is limited due to the lack of bedside methods. The aim of this pilot study was to investigate the reliability of the transpulmonary ultrasound dilution (TPUD) technique as a possible method for estimating EVLW in a neonatal animal model. Pulmonary edema was induced in 11 lambs by repeated surfactant lavages. In between the lavages, EVLW indexed by bodyweight was estimated by TPUD (EVLWItpud) and transpulmonary dye dilution (EVLWItpdd) (n = 22). Final EVLWItpud measurements were also compared with EVLWI estimations by gold standard post mortem gravimetry (EVLWIgrav) (n = 6). EVLWI was also measured in two additional lambs without pulmonary edema. Bland-Altman plots showed a mean bias between EVLWItpud and EVLWItpdd of -3.4 mL/kg (LOA +/- 25.8 mL/kg) and between EVLWItpud and EVLWIgrav of 1.7 mL/kg (LOA +/- 8.3 mL/kg). The percentage errors were 109 and 43 % respectively. The correlation between changes in EVLW measured by TPUD and TPDD was r2 = 0.22. Agreement between EVLWI measurements by TPUD and TPDD was low. Trending ability to detect changes between these two methods in EVLWI was questionable. The accuracy of EVLWItpud was good compared to the gold standard gravimetric method but the TPUD lacked precision in its current prototype. Based on these limited data, we believe that TPUD has potential for future use to estimate EVLW after adaptation of the algorithm. Larger studies are needed to support our findings.
This item appears in the following Collection(s)
- Academic publications [229133]
- Electronic publications [111625]
- Faculty of Medical Sciences [87757]
- Open Access publications [80441]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.