Preliminary results using a newly developed projection method to visualize vascular anatomy prior to DIEP flap breast reconstruction
Publication year
2015Source
Journal of Plastic, Reconstructive and Aesthetic Surgery, 68, 3, (2015), pp. 390-4ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Plastic Surgery
Medical Imaging
Journal title
Journal of Plastic, Reconstructive and Aesthetic Surgery
Volume
vol. 68
Issue
iss. 3
Page start
p. 390
Page end
p. 4
Subject
Radboudumc 0: Other Research RIHS: Radboud Institute for Health Sciences; Radboudumc 16: Vascular damage RIHS: Radboud Institute for Health Sciences; Radboudumc 17: Women's cancers RIHS: Radboud Institute for Health SciencesAbstract
INTRODUCTION: In a deep inferior epigastric perforator (DIEP) flap breast reconstruction, computed tomography angiography (CTA) is currently considered as the gold standard in preoperative imaging for this procedure. Unidirectional Doppler ultrasound (US) is frequently used; however, this method does not distinguish the main axial vessels from perforator arteries at the height of the fascia, it has a limited penetration depth, and it cannot assess the branching patterns of the deep inferior arteries. A new method and system were developed, which consisted of a video projector preoperatively displaying the location and intramuscular course of the artery perforators and subcutaneous branching on the patient's abdomen. METHOD: All patients (n = 9) underwent a standard protocol: a preoperative CTA was performed and the DIEPs were localized using a unidirectional Doppler probe. In addition, a three-dimensional (3D) reconstruction of the perforator locations based on CTA was projected on the abdomen of the patients. All projected perforator locations were assessed using a unidirectional Doppler probe. The intraoperative results were collected for comparison. RESULTS: A total of 88 locations were marked with the use of unidirectional Doppler and a total of 100 perforators were projected (p = 0.38). In 98 out of 100 projected perforator locations, a Doppler signal was audible. The intraoperative results demonstrate that 19 out of 34 transplanted perforators were correctly identified with unidirectional Doppler (56.9% +/- 31.4%), where the projection method properly revealed 29 locations (84.3% +/- 25.8%) (p = 0.030). CONCLUSION: The projection method is not only capable of providing more information and identifying more perforators used for transplantation than unidirectional Doppler probing but also more accurate in pointing out the corresponding perforator found intraoperatively.
This item appears in the following Collection(s)
- Academic publications [246515]
- Faculty of Medical Sciences [93308]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.