Resolution, sensitivity, and in vivo application of high-resolution computed tomography for titanium-coated polymethyl methacrylate (PMMA) dental implants
Fulltext:
136716.pdf
Embargo:
until further notice
Size:
687.7Kb
Format:
PDF
Description:
Publisher’s version
Publication year
2014Source
Clinical Oral Implants Research, 25, 3, (2014), pp. 359-65ISSN
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Dentistry
Journal title
Clinical Oral Implants Research
Volume
vol. 25
Issue
iss. 3
Page start
p. 359
Page end
p. 65
Subject
Radboudumc 10: Reconstructive and regenerative medicine RIMLS: Radboud Institute for Molecular Life SciencesAbstract
OBJECTIVES: The aims of this study were (i) to determine the spatial resolution and sensitivity of micro- versus nano-computed tomography (CT) techniques and (ii) to validate micro- versus nano-CT in a dog dental implant model, comparative to histological analysis. MATERIAL AND METHODS: To determine spatial resolution and sensitivity, standardized reference samples containing standardized nano- and microspheres were prepared in polymer and ceramic matrices. Thereafter, 10 titanium-coated polymer dental implants (3.2 mm in O by 4 mm in length) were placed in the mandible of Beagle dogs. Both micro- and nano-CT, as well as histological analyses, were performed. RESULTS: The reference samples confirmed the high resolution of the nano-CT system, which was capable of revealing sub-micron structures embedded in radiodense matrices. The dog implantation study and subsequent statistical analysis showed equal values for bone area and bone-implant contact measurements between micro-CT and histology. However, because of the limited sample size and field of view, nano-CT was not rendering reliable data representative of the entire bone-implant specimen. CONCLUSIONS: Micro-CT analysis is an efficient tool to quantitate bone healing parameters at the bone-implant interface, especially when using titanium-coated PMMA implants. Nano-CT is not suitable for such quantification, but reveals complementary morphological information rivaling histology, yet with the advantage of a 3D visualization.
This item appears in the following Collection(s)
- Academic publications [243908]
- Electronic publications [130674]
- Faculty of Medical Sciences [92803]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.