Assessment of Needle Guidance Devices for Their Potential to Reduce Fluoroscopy Time and Operator Hand Dose during C-Arm Cone-Beam Computed Tomography-Guided Needle Interventions

Fulltext:
128508.pdf
Embargo:
until further notice
Size:
368.3Kb
Format:
PDF
Description:
publisher's version
Publication year
2013Source
Journal of Vascular and Interventional Radiology, 24, (2013), pp. 901-906ISSN
Publication type
Article / Letter to editor

Display more detailsDisplay less details
Organization
Radiology
Journal title
Journal of Vascular and Interventional Radiology
Volume
vol. 24
Page start
p. 901
Page end
p. 906
Subject
NCEBP 14: Cardiovascular diseases; ONCOL 5: Aetiology, screening and detection; NCEBP 14: Cardiovascular diseases ONCOL 5: Aetiology, screening and detectionAbstract
PURPOSE: To assess whether the use of needle guidance devices can reduce fluoroscopy time and operator hand dose during cone-beam computed tomography-guided needle interventions. MATERIALS AND METHODS: The freehand technique was compared with techniques employing two distinct needle holders and a ceiling-mounted laser guidance technique. Laser guidance was used either alone or in combination with needle holders. Four interventional radiologists were instructed to reach predetermined targets in an abdominal phantom using these techniques. Each operator used all six techniques three times. Fluoroscopy time, procedure time, operator hand dose, and needle tip deviation were obtained for all simulated needle interventions. All data are presented as median (ranges). RESULTS: All procedures were successfully completed within 2-4 minutes, resulting in a deviation from target of 0.8 mm (0-4.7). In freehand procedures, the fluoroscopy time to reach the target was 50 seconds (31-98 s). Laser guidance, used alone or in combination with needle holders, reduced fluoroscopy time to 31 seconds (14-68 s) (P<.02). The operator hand dose in freehand procedures was 275 μSv (20-603 μSv). Laser guidance alone or in combination with needle holders resulted in a reduction of the hand dose to<36 μSv (5-82 μSv) per procedure (P<.001). There were no statistically significant effects on hand dose levels or fluoroscopy time when the needle holders were employed alone. CONCLUSIONS: Compared with the freehand technique, all three tested needle guidance devices performed with equivalent efficiency in terms of accuracy and procedure time. Only the addition of laser guidance was found to reduce both fluoroscopy time and operator hand dose.