Comparison of automated 4-chamber cardiac views versus axial views for measuring right ventricular enlargement in patients with suspected pulmonary embolism.
Publication year
2012Source
European Journal of Radiology, 81, 2, (2012), pp. 218-22ISSN
Annotation
01 februari 2012
Publication type
Article / Letter to editor

Display more detailsDisplay less details
Organization
Radiology
Journal title
European Journal of Radiology
Volume
vol. 81
Issue
iss. 2
Page start
p. 218
Page end
p. 22
Subject
ONCOL 5: Aetiology, screening and detectionAbstract
PURPOSE: Compare the right ventricle to left ventricle (RV/LV) diameter ratio obtained from axial pulmonary CT angiograms (CTPA) with those derived from automatically generated 4-chamber (4-CH) reformats in patients with suspected pulmonary embolism (PE). METHODS: In this institutional review board-approved study we included 120 consecutive non ECG-gated CTPA from 3 institutions (mean age 60 +/- 16 years; 71 women). Twenty 64-slice CTPA with PE and 20 without PE were selected per institution. For each patient the RV/LV diameter ratio was obtained from both axial CTPA images and automatically generated 4-CH reformats. Measurements were performed twice in two separated sessions by 2 experienced radiologists and 2 residents. The differences between the measurements on both views were evaluated. RESULTS: The 4-CH view was successfully obtained in 113 patients. The mean axial and 4-CH diameter ratios were comparable for three of the four readers (p = 0.56, p = 0.13, p = 0.08). Although the mean diameters (1.0 and 1.03 respectively) for one resident were significantly different (p = 0.013), the difference of 0.03 seems negligible in clinical routine. Three readers achieved equally high intra-reader agreements with both measurements (ICCs of 0.94, 0.95 and 0.96), while one reader showed a different variability with ICCs of 0.96 for the axial view and 0.91 for the 4-CH view. The inter-reader agreement was equally high for both measurement types with ICCs of 0.95 and 0.94, respectively. CONCLUSION: In patients with suspected PE, RV/LV diameters ratio can be measured with the same reproducibility and accuracy using an automatically generated 4-CH view compared to the axial view.
This item appears in the following Collection(s)
- Academic publications [229289]
- Faculty of Medical Sciences [87821]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.