Stand-alone performance of a computer-assisted detection prototype for detection of acute pulmonary embolism: a multi-institutional comparison.
Publication year
2012Source
British Journal of Radiology, 85, 1014, (2012), pp. 758-64ISSN
Annotation
01 juni 2012
Publication type
Article / Letter to editor
Display more detailsDisplay less details
Organization
Radiology
Journal title
British Journal of Radiology
Volume
vol. 85
Issue
iss. 1014
Page start
p. 758
Page end
p. 64
Subject
ONCOL 5: Aetiology, screening and detection; Medical Imaging - Radboud University Medical Center; NCEBP 14: Cardiovascular diseases ONCOL 5: Aetiology, screening and detectionAbstract
OBJECTIVE: To assess whether the performance of a computer-assisted detection (CAD) algorithm for acute pulmonary embolism (PE) differs in pulmonary CT angiographies acquired at various institutions. METHODS: In this retrospective study, we included 40 consecutive scans with and 40 without PE from 3 institutions (n = 240) using 64-slice scanners made by different manufacturers (General Electric; Philips; Siemens). CAD markers were classified as true or false positive (FP) using independent evaluation by two readers and consultation of a third chest radiologist in discordant cases. Image quality parameters were subjectively scored using 4/5-point scales. Image noise and vascular enhancement were measured. Statistical analysis was done to correlate image quality of the three institutions with CAD stand-alone performance. RESULTS: Patient groups were comparable with respect to age (p = 0.22), accompanying lung disease (p = 0.12) and inpatient/outpatient ratio (p = 0.67). The sensitivity was 100% (34/34), 97% (37/38) and 92% (33/36), and the specificity was 18% (8/44), 15% (6/41) and 13% (5/39). Neither significantly differed between the institutions (p = 0.21 and p = 0.820, respectively). The mean number of FP findings (4.5, 6.2 and 3.7) significantly varied (p = 0.02 and p = 0.03), but median numbers (2, 3 and 3) were comparable. Image quality parameters were significantly associated with the number of FP findings (p<0.05) but not with sensitivity. After correcting for noise and vascular enhancement, the number of FPs did not significantly differ between the three institutions (p = 0.43). CONCLUSIONS: CAD stand-alone performance is independent of scanner type but strongly related to image quality and thus scanning protocols.
This item appears in the following Collection(s)
- Academic publications [246423]
- Faculty of Medical Sciences [93307]
Upload full text
Use your RU credentials (u/z-number and password) to log in with SURFconext to upload a file for processing by the repository team.