Title: Interlaboratory round robin on cantilever calibration for AFM force spectroscopy.
Author(s): Riet, J. te (298202735)
Katan, A.J.
Rankl, C.
Stahl, S.W.
Buul, A.M. van
Phang, I.Y.
Gomez-Casado, A.
Schon, P.
Gerritsen, J.W. (298986108)
Cambi, A. (284845647)
Rowan, A.E. (298979357)
Vancso, G.J.
Jonkheijm, P.
Huskens, J.
Oosterkamp, T.H.
Gaub, H.
Hinterdorfer, P.
Figdor, C.G. (067631614)
Speller, S.
Publication year: 2011
Document type: Article / Letter to editor
Journal: Ultramicroscopy
ISSN: 0304-3991
Volume: vol. 111
Issue: iss. 12
Start page: p. 1659
End page: p. 1669
Abstract: Single-molecule force spectroscopy studies performed by Atomic Force Microscopes (AFMs) strongly rely on accurately determined cantilever spring constants. Hence, to calibrate cantilevers, a reliable calibration protocol is essential. Although the thermal noise method and the direct Sader method are frequently used for cantilever calibration, there is no consensus on the optimal calibration of soft and V-shaped cantilevers, especially those used in force spectroscopy. Therefore, in this study we aimed at establishing a commonly accepted approach to accurately calibrate compliant and V-shaped cantilevers. In a round robin experiment involving eight different laboratories we compared the thermal noise and the Sader method on ten commercial and custom-built AFMs. We found that spring constants of both rectangular and V-shaped cantilevers can accurately be determined with both methods, although the Sader method proved to be superior. Furthermore, we observed that simultaneous application of both methods on an AFM proved an accurate consistency check of the instrument and thus provides optimal and highly reproducible calibration. To illustrate the importance of optimal calibration, we show that for biological force spectroscopy studies, an erroneously calibrated cantilever can significantly affect the derived (bio)physical parameters. Taken together, our findings demonstrated that with the pre-established protocol described reliable spring constants can be obtained for different types of cantilevers.
Subject: NCMLS 1B: Immune Regulation
Organization: Tumorimmunology
UMCN Extern
Appears in Collections:Academic bibliography

Please use this identifier to cite or link to this item: http://hdl.handle.net/2066/97053

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

  DSpace Software Copyright © 2002-2011  Duraspace - Feedback