|
|
DSpace at RU >
University Library >
Academic bibliography >
Files in This Item:
| File |
Description |
Size | Format |
| publisher's version | 219.5 kB | Adobe PDF | Under Embargo
|
|
| Title: | Can FDG-PET assist in radiotherapy target volume definition of metastatic lymph nodes in head-and-neck cancer? |
| Author(s): | Schinagl, D.A.X. Hoffmann, A.L. Vogel, W.V. (298981858) Dalen, J.A. van (235199656) Verstappen, S.M.M. Oyen, W.J.G. (09080497X) Kaanders, J.H.A.M. (114575762) |
| Publication year: | 2009 |
| Document type: | Article / Letter to editor |
| Journal: | Radiotherapy and Oncology |
| ISSN: | 0167-8140 |
| Volume: | vol. 91 |
| Issue: | iss. 1 |
| Start page: | p. 95 |
| End page: | p. 100 |
| Abstract: | BACKGROUND AND PURPOSE: The role of FDG-PET in radiotherapy target volume definition of the neck was evaluated by comparing eight methods of FDG-PET segmentation to the current CT-based practice of lymph node assessment in head-and-neck cancer patients. MATERIALS AND METHODS: Seventy-eight head-and-neck cancer patients underwent coregistered CT- and FDG-PET scans. Lymph nodes were classified as "enlarged" if the shortest axial diameter on CT was 10mm, and as "marginally enlarged" if it was 7-10mm. Subsequently, lymph nodes were assessed on FDG-PET applying eight segmentation methods: visual interpretation (PET(VIS)), applying fixed thresholds at a standardized uptake value (SUV) of 2.5 and at 40% and 50% of the maximum signal intensity of the primary tumor (PET(SUV), PET(40%), PET(50%)) and applying a variable threshold based on the signal-to-background ratio (PET(SBR)). Finally, PET(40%N), PET(50%N) and PET(SBRN) were acquired using the signal of the lymph node as the threshold reference. RESULTS: Of 108 nodes classified as "enlarged" on CT, 75% were also identified by PET(VIS), 59% by PET(40%), 43% by PET(50%) and 43% by PET(SBR). Of 100 nodes classified as "marginally enlarged", only a minority were visualized by FDG-PET. The respective numbers were 26%, 10%, 7% and 8% for PET(VIS), PET(40%), PET(50%) and PET(SBR). PET(40%N), PET(50%N) and PET(SBRN), respectively, identified 66%, 82% and 96% of the PET(VIS)-positive nodes. CONCLUSIONS: Many lymph nodes that are enlarged and considered metastatic by standard CT-based criteria appear to be negative on FDG-PET scan. Alternately, a small proportion of marginally enlarged nodes are positive on FDG-PET scan. However, the results are largely dependent on the PET segmentation tool used, and until proper validation FDG-PET is not recommended for target volume definition of metastatic lymph nodes in routine practice. |
| Subject: | ONCOL 3: Translational research ONCOL 5: Aetiology, screening and detection |
| Organization: | Nuclear Medicine Radiation Oncology Radiology UMCN Extern |
| Appears in Collections: | Academic bibliography
|
|
Please use this identifier to cite or link to this item:
http://hdl.handle.net/2066/80379
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|
|