| Abstract: | BACKGROUND: HLA class I peptide tetramers represent powerful diagnostic tools for detection and monitoring of antigen-specific CD8(+) T cells. The impetus for the current multicenter study is the critical need to standardize tetramer flow cytometry if it is to be implemented as a routine diagnostic assay. Hence, the European Working Group on Clinical Cell Analysis set out to develop and evaluate a single-platform tetramer-based method that used cytomegalovirus (CMV) as the antigenic model. METHODS: Absolute numbers of CMV-specific CD8(+) T cells were obtained by combining the percentage of tetramer-binding cells with the absolute CD8(+) T-cell count. Six send-outs of stabilized blood from healthy individuals or CMV-carrying donors with CMV-specific CD8(+) T-cell counts of 3 to 10 cells/microl were distributed to 7 to 16 clinical sites. These sites were requested to enumerate CD8(+) T cells and, in the case of CMV-positive donors, CMV-specific subsets on three separate occasions using the standard method. RESULTS: Between-site coefficients of variation of less than 10% (absolute CD8(+) T-cell counts) and approximately 30% (percentage and absolute numbers of CMV-specific CD8(+) T cells) were achieved. Within-site coefficients of variation were approximately 5% (absolute CD8(+) T-cell counts), approximately 9% (percentage CMV-specific CD8(+) T cells), and approximately 17% (absolute CMV-specific CD8(+) T-cell counts). The degree of variation tended to correlate inversely with the proportion of CMV-specific CD8(+) T-cell subsets. CONCLUSIONS: The single-platform MHC tetramer-based method for antigen-specific CD8(+) T-cell counting has been evaluated by a European group of laboratories and can be considered a reproducible assay for routine enumeration of antigen-specific CD8(+) T cells. |
| Subject: | UMCN 1.2: Molecular diagnosis, prognosis and monitoring |
| Organization: | UMCN Extern CHL |
| Appears in Collections: | Academic bibliography
|
|
Please use this identifier to cite or link to this item:
http://hdl.handle.net/2066/58561
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
|
|