Title: Measurement of regional rates of cerebral protein synthesis with L-[1-11C]leucine and PET with correction for recycling of tissue amino acids: II. Validation in rhesus monkeys.
Author(s): Smith, C.B.
Schmidt, K.C.
Qin, M.
Burlin, T.V.
Cook, M.P.
Kang, J.
Saunders, R.C.
Bacher, J.D.
Carson, R.E.
Channing, M.A.
Eckelman, W.C.
Herscovitch, P.
Laverman, P. (204254523)
Vuong, B.K.
Publication year: 2005
Document type: Article / Letter to editor
Journal: Journal of Cerebral Blood Flow and Metabolism
ISSN: 0271-678X
Volume: vol. 25
Issue: iss. 5
Start page: p. 629
End page: p. 640
Abstract: The confounding effect of recycling of amino acids derived from tissue protein breakdown into the precursor pool for protein synthesis has been an obstacle to adapting in vivo methods for determination of regional rates of cerebral protein synthesis (rCPS) to positron emission tomography (PET). We used a kinetic modeling approach to estimate lambda, the fraction of the precursor pool for protein synthesis derived from arterial plasma, and to measure rCPS in three anesthetized adult monkeys dynamically scanned after a bolus injection of L-[1-11C]leucine. In the same animals, lambda was directly measured in a steady-state terminal experiment, and values showed excellent agreement with those estimated in the PET studies. In three additional monkeys rCPS was determined with the quantitative autoradiographic L-[1-14C]leucine method. In whole brain and cerebellum, rates of protein synthesis determined with the autoradiographic method were in excellent agreement with those determined with PET, and regional values were in good agreement when differences in spatial resolution of the two methods were taken into account. Low intrasubject variability was found on repeated PET studies. Our results in anesthetized monkey indicate that, by using a kinetic modeling approach to correct for recycling of tissue amino acids, quantitatively accurate and reproducible measurement of rCPS is possible with L-[1-11C]leucine and PET.
Subject: UMCN 1.1: Functional Imaging
Organization: UMCN Extern
Nuclear Medicine
Appears in Collections:Academic bibliography

Please use this identifier to cite or link to this item: http://hdl.handle.net/2066/47505

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

  DSpace Software Copyright © 2002-2011  Duraspace - Feedback